Strainers are equipped with a replaceable mesh from stainless steel in various mesh sizes.
GEA strainers are designed for installation in the refrigerant circulation of industrial refrigeration systems. They are equipped with a replaceable mesh from stainless steel in various mesh sizes. The insert is self-centring and is held in position by the cover. The medium flows through the mesh insert from the inside to the outside.
SS Strainers | |
material | steel or stainless steel |
nominal size | DN 10-350 |
nominal pressure level | PS 25, PS 40, PS 63, PS 160 |
temperature range for standard valves | -60 °C bis +150 °C |
temperature range for HT valve series | -10 °C bis +200 °C |
connection | butt welding and flanged ends as per DIN and ANSI
brazed ends threaded ends |
additional information | available mesh sizes (µm): 63 / 80 / 100 / 135 / 150 / 200 / 250 / 500 |