D-tec® valve line
D-tec® double chamber valves are used for the mixproof shut-off of incompatible products at pipe junctions. The valves are an ideal fit for UltraClean applications but can also be operated aseptically.
Housing
Housings for D-tec® double chamber valves are available with three or four connection ports. The valves are produced with standard butt-weld connections suitable for orbital welding by default. Mixed connection port sizes as well as various pipe connections are available upon request.
Internal assembly
The hermetically sealing D-tec® stem diaphragm is the key element of every D-tec® valve. It is characterized by a very long service life, high dimensional stability with temperature resilience and cleanability. The internal assembly of a D-tec® double chamber valve includes two valve seat seals by default which can be equipped with soft-sealing (i.e. EPDM) or hard-sealing (TEFASEP® gold) materials. The lower valve seat corresponds with the nominal width of the valve.
Actuator
The main valve is equipped with two actuators by default. The main actuator is used to move the valve from its normally closed fail-safe position to the fully open position by applying pressurized air to the internal air supply. The lifting actuator on the other hand is used to lift the two valve seats of the main valve independently during CIP or SIP.
Lantern
The lantern connects the lift actuator with the product-wetted parts and simultaneously prevents the system from heat transfer between these two valve sections. The lantern has an important supporting and clamping function for the upper D-tec® stem diaphragm and is furthermore designed for a safe and easy visual detection of leakages.
Side valves
The sterile chamber includes an inlet and an outlet valve by default. The fail-safe position (NC or NO) of both side valves can be chosen independently from each other. The outlet can be equipped with integrated temperature probe which enables temperature measuring in the sterile chamber. In addition, the outlet can be configured with a divert valve to directly apply a sterile media also to the drain side of the valve.
Feedback units
D-tec® double chamber valves can be either equipped with open feedback units or T.VIS® control tops by default. The degree of automation at the valve can be adapted to customer needs by means of using one, two or three independent control tops.
Item | Size |
Nominal pressure valve | 6 bar |
Closing pressure | 6 bar |
Control air pressure | 6 bar |
Hermetic sealing element | D-tec® diaphragms |
Valve seat seal material | EPDM |
Surface quality in product area | Ra ≤ 0.8 |
Material quality in product area | AISI 316L |
Max. operating temperature | + 135 °C |
Max. sterilization temperature | + 150° for 30 min |
Item | Size |
Nominal pressure valve | 6 bar |
Closing pressure | 6 bar |
Control air pressure | 6 bar |
Hermetic sealing element | D-tec® diaphragm |
Valve seat seal material | TEFASEP® gold |
Surface quality in product area | Ra ≤ 0.8 |
Material quality in product area | AISI 316L |
Max. operating temperature | + 150 °C |
Max. sterilization temperature | + 160° for 30 min |
Shut-off Valve D-tec® N/DV – hard-sealing with TEFASEP® gold
Thanks to the hermetically sealing stem diaphragm D-tec® valves contribute to higher product quality and longer product shelf-life as often demanded with UltraClean applications. The innovative connection between valve stem and stem diaphragm minimizes mechanical stress of the diaphragm during switching operations. The D-tec® stem diaphragm sets standards for the service life at proven temperature resilience and cleanability.
The D-tec® valve line is based on the VARIVENT® valve line and offers many advantages because of this – e.g. a high level of flexibility in terms of valve configuration. The result: Economic efficiency for the system operator and optimized stock handling due to reduced diversity of parts at proven quality.
All of our D-tec® valves can be equipped with T.VIS® control tops. They integrate and combine our valves into the automated process plant.
UltraClean applications
The most relevant product parameter for UltraClean applications is shelf-life. It is mostly determined by the pH-value and the aw-value of the product. In addition, sensory properties need to be considered as well as the logistical chain of distribution. One of the advantages of UltraClean processing is the reduced quantity of preservatives needed for maintaining the shelf-life of the product.
Valve type | Metric | Inch OD |
Shut-off Valves D-tec® N/DV | DN 25 – DN 100 | 1" – 4" |
Divert Valves D-tec® W/DV | DN 25 – DN 100 | 1" – 4" |
Control Valves D-tec® P/DV | DN 40 – DN 100 | 1.5" – 4" |
Tank Bottom Valves D-tec® N/DV | DN 25 – DN 100 | 1” – 4” |
Double Chamber Valves D-tec® D/DV | DN 40 – DN 100 | 1.5” – 4” |
Divert valves of the D-tec® valve line are characterized by their hermetically sealing stem diaphragm.
Control valves of the D-tec® valve line are characterized by their hermetically sealing stem diaphragm.
Tank bottom valves of the D-tec® valve line are characterized by their hermetically sealing stem diaphragm.
Shut-off valves of the D-tec® valve line are characterized by their hermetically sealing stem diaphragm.
Healthy and happy cows are the key to successful and sustainable milk production. Keeping their cows healthy, therefore, is at the heart of every dairy farmer’s effort. Many factors influence the well-being of a cow, such as...
Industries across the board are working hard to meet net-zero targets while navigating stringent decarbonization regulations and legislation. At the same time, companies must balance growing demands for quality, product development...
Coffee, cocoa, milk, meat, fish and eggs – these daily staples rely heavily on intensive agriculture. With the rise of new food technologies, we have more sustainable alternatives. We sat down with Dr. Reimar Gutte, Senior Vice...