Double-seat valves

VARIVENT® Mixproof shut-off valves with seat lifting

VARIVENT® double-seat valves are used for mixproof shut-off of incompatible products at pipe junctions.

Function

When the valve is closed (non-actuated position), there are always two seals between the separated pipelines. If one seal is defective, the resulting leakage will be directed through the leakage outlet into the periphery, without mixing with the product in the second pipeline.

This method enables that there is no mixing between the products from two pipelines.

Application Examples

To accommodate the different requirements of various industries, applications and processes, we have a variety of mixproof shut-off valves in our portfolio. The selection scheme on pages provides an overview of all the options.

VARIVENT® long-stroke valves are used for manufacturing products with relatively large particles or for viscous products, such as strawberry yoghurt.

Special Features

  • Certified, hygienic configuration
  • Metallic stop
  • Flexibility because of the modular principle
  • Proven seal geometry
  • Mixproof separation
  • Different valve configurations available
  • Separate lifting actuator for lifting both valve discs
  • Optional spray cleaning connection for cleaning the leakage chamber

Selection of hygienic GEA valves - mixproof valves

Selection of hygienic GEA valves - mixproof valves

Variety of types

The different variants of the VARIVENT® double-seat valve make it possible to select valves that are optimally adapted to the process. The axial sealing valve types D and B entail a small switching leakage during each switching procedure, but they notably have a very long service life with the axial seals. The radial sealing valve type R, on the other hand, offers the advantage of switching nearly without any switching leakage. Valve types B and R are additionally characterized by a balancer in the lower valve housing. This enables the valve to reliably remain in the closed position even if there are water hammers in the lower pipeline. The valve type MX is additionally equipped with a balancer on the double disk and valve disk. Thanks to specially shaped balancers in both pipelines, the valve remains stable in the closed position even in the event of water hammer and, on the other hand, retains its full ability to act even in the case of hydraulic lock or thermal expansion of the medium.

Sizes
Double-seat valvesLong-stroke double-seat valvesMX valves
DN 25 – DN 150DN 65 – DN 150DN 40 – DN 150
OD 1" – OD 6"OD 3" – OD 4"OD 1.5“ – OD 6“
IPS 2" – IPS 6"IPS 2" – IPS 4"

The structure of the VARIVENT® modular system means that many optional versions are available for adapting the valve optimally to the process. Please refer to the options section in the catalog for information about these.

Switching leakage

In axial sealing double-seat valves, with every switching procedure there is a short time during which the lower valve disc is neither in contact with the middle seal of the upper valve disc, nor has it reached the axial seat surface of the seat ring. During this brief moment liquid can percolate through the resulting gap into the leakage chamber and flow out into the atmosphere. This is referred to as the switching leakage.

In radial sealing double-seat valves, this gap does not occur during the switching procedure, which means the switching leakage is reduced to a minimum (possibility of product residues adhering to the metallic surfaces).

Water hammer safety

If there is a water hammer in the lower pipeline, the force of the water hammer acts on the lower valve disc and could exceed the locking force of the actuator spring.

This gives rise to the danger of the lower valve disc being lifted by the pressure in the pipeline.

In axial sealing double-seat valves, this would result in a connection to the atmosphere, leading to a leak (see switching leakage). The connection to the atmosphere would also cause a sudden reduction in the excess pressure in the pipeline. Then the actuator spring would close the valve again.

Valves with a lower balancer are available to prevent the lower valve disc from lifting during a water hammer in the lower pipeline. With its downward-facing compensation surface, the balancer adjusts out the operating direction of the pressure and prevents movement of the lower valve disc up to a particular excess pressure.

Radial sealing double-seat valves are always equipped with this lower balancer to prevent the opening movement of the lower valve disc.

Both valve disks of the valve type MX from GEA are equipped with balancers. The valve is thus pressure-resistant in the closed valve position in both the upper and lower pipelines and enables switching when the product is enclosed.

Technical data

Please refer to the catalog for more information.

Type
D_L, D_C & D_L/V, D_C/V (Longstroke)
Type
B_L, B_C
Type
R_L, R_C
Type
 L_HL, L_HC, L_SL, L_SC
Material in contact with the product1.4404 / AISI 316 L
Material not in contact with the product1.4301 / AISI 304
Seal material in contact with the productEPDM, FKM, HNBR
Ambient temperature0 to 45 °C
Air supply pressure6 bar (87 psi)
Product pressure5 bar (73 psi)5 bar (73 psi)5 bar (73 psi)7 bar (101 psi)
Water hammer safetyup to 25 bar30 bar up to
DN 50, OD 2",
IPS 2"
50 bar from
DN 65, OD 2 ½", IPS 3"
Surface in contact with the productDN, OD
Ra ≤ 0.8 μm
IPS Ra ≤ 1.2 µm
DN, OD
Ra ≤ 0.8 μm
IPSR≤ 1.2 µm
DN, OD
Ra ≤ 0.8 μm
IPS Ra ≤ 1.2 µm
Ra ≤ 0.8 μm   

External housing surfaceMatte blasted
Control and feedback systemConnection 0 (without control top)
Actuator typePneumatic actuator air / spring
Connection fittingsWelding end
IdentificationAdhesive ID tag
Valve seat versionClamped or welded seat ringClamped or welded seat ringClamped or welded seat ringWelded seat ring
CertificatesEHEDG, 3A, CE3A, CEEHEDG, 3A, CE3A, CE

Downloads

Related Videos

GEA VARIVENT® Mixproof valve type MX

GEA Insights

Human hands brought together to form a circle

In for the better: Community engagement at GEA

To support community engagement, GEA offers employees one day of paid time off per year.

How a digital rotary parlor supports sustainable dairy farming

How do you lead a dairy farm into the next generation while ensuring a sustainable future and animal welfare while managing increasing complexity? This is a question almost every dairy farmer around the world must consider. The...

GEA misison 30 logo

A strategy for the better: CEO interview on GEA's Mission 30

After reaching its Mission 26 targets two years early, GEA launches Mission 2030 strategy with focus on growth, value and making a positive impact.

Receive news from GEA

Stay in touch with GEA innovations and stories by signing up for news from GEA.

Need assistance?

We are here to help! With just a few details we will be able to respond to your inquiry.