Devices to protect refrigeration systems from excess pressure.

DUAL SAFETY VALVE COMBINATIONS

Devices to protect refrigeration systems and their components from excess pressure. The arrangement comprises of one 3-way valve and two safety valves dependent or independent on back pressure.

WVR-SVU, WVR-SVA Dual Safety Valves and WVR SVA / SVU Dual Safety Valves with Chain Drive

GEA dual safety relief valves are designed for installation in the refrigerant cycles of industrial refrigeration systems. The safety valves which are dependent of back pressure protect refrigeration systems and their components from excess pressure (see also EN 378 part 2). They comply with the technical regulations of the German Technical Control Board (TÜV) and with AD2000 regulations. Once the set response pressure is reached GEA safety valves begin to open. They open within a 10 % pressure increase until the designed limit of the lift is reached. When the pressure drops again they start closing once the set response pressure is reached. They close completely within a pressure drop of 10 % below the set response pressure. The 3-way valve enables easy checks and maintenances of the safety valves without the system’s operation to be interrupted. One of the two outlet nozzles is always open whereas the other one is closed. So one safety valve can be inspected or even disassembled while the other one remains in service to protect the system.

WVR AL SVA / SVU Dual Safety Valves

They are available with safety valves either back pressure dependent or independent to protect the refrigeration systems and their components from excess pressure (see also EN 378 part 2). They comply with AD2000 regulations. After their initial response GEA safety valves open within 10 % of pressure increase up to the designed limitation. They close within a pressure drop of 10 % below the response pressure. The 3-way valve enables easy checks and maintenances of the safety valves without the system’s operation to be interrupted. One of the two outlet nozzles is always open whereas the other one is closed. So one safety valve can be checked or removed while the other one remains in service to protect the system. The compact design of the WVR AL requires minimum space and enables horizontal and vertical assembly. Compared to steel and stainless steel valve types the weight could be reduced by up to 30 % by using salt-water resistant aluminum EN AW-6082 as body material.

Technical Features

  • 3-way valves are made of aluminum, safety valves are available in steel or stainless steel
  • Selection of body material as per German DIN EN12284, AD2000 Series W
  • Working mediums: refrigerants as per EN 378 p. 1, e.g. NH3, R134a, R290 (propane), R507 and blends with refrigerator oil; neutral, gaseous and liquid mediums; glycol-based cold brine
  • Installation position: vertical as per AD2000-leaflet A2 and horizontal
  • Available valve seat seals (for safety valves): 
    • WVR-SVUA / WVR-SVAA / WVR AL-SVAA / WVR AL-SVUA  : PTFE seal, can be used at temperatures of -60 °C to +180 °C, cannot be used for response pressures of less than 10 bar. 
    • WVR-SVUB / WVR-SVAB / WVR AL-SVAB / WVR AL-SVUB: elastomer seal, can be used at temperatures of -50 °C to +110 °C
WVR-SVA Dual
Safety Valves
WVR-SVU Dual
Safety Relief Valves
WVR AL SVA / SVU Dual
Safety Valves
WVR SVA / SVU Dual
Safety Valves with Chain Drive
materialsteel or stainless steelsteel or stainless steelaluminum (3-way valve) steel
or stainless steel (safety valves)
steel or stainless steel
nominal size (inlet\outlet)DN 15/15 – 65/100DN 15/15 – 65/100DN 15-32DN 15-100
nominal pressure levelPS 25, PS 40, PS 63PS 25, PS 40, PS 63PS 25, PS 40, PS 63PS 25, PS 40, PS 63
temperature range for
standard valves
WVR-SVAA: -60 °C to +180 °C 
WVR-SVAB: -50 °C to +110 °C
WVR-SVUA: -60 °C to +180 °C 
WVR-SVUB: -50 °C to +110 °C
WVR AL-SVAA / SVUA: -60 °C to +180 °C 
WVR AL-SVAB / SVUB: -50 °C to +110 °C
WVR SVAA / SVUA: -60 °C to +180 °C 
WVR SVAB / SVUB: -50 °C to +110 °C
connectionflanged ends as per DIN and ANSI
threaded ends
flanged ends as per DIN and ANSI
threaded ends
flanged ends as per DIN and ANSI
flanged ends as per DIN and ANSI
additional informationavailable with bursting discs,
bursting disc holder
and excess flow valve
available with bursting discs,
bursting disc holder
and excess flow valve
available with bursting discs,
bursting disc holder
and excess flow valve
available with bursting discs,
bursting disc holder
and excess flow valve
GEA AWP WVR-SVA | SVU Safety Valve Combination

Safety Valve Combinations type WVR-SVA & WVR-SVU

Downloads

Approfondimenti GEA

Un impianto di mungitura su misura favorisce il benessere degli animali e il buon andamento dell'azienda

Animali sani e a loro agio sono essenziali per una produzione di latte sostenibile e proficua. Il mantenimento di una buona salute degli animali è quindi la preoccupazione principale di ogni allevatore. Sono molti i fattori che...

Azzerare le emissioni nette con le soluzioni di progettazione complete di GEA

L'industria globale sta lavorando intensamente per raggiungere gli obiettivi di azzeramento delle emissioni nette e al contempo adeguarsi alle severe normative e legislazioni in materia di decarbonizzazione. Parallelamente, le...

Nuovi cibi in tavola: al lavoro per l'alimentazione del futuro

Caffè, cacao, latte, carne, pesce e uova: questi prodotti di prima necessità dipendono fortemente dall'agricoltura intensiva. Grazie allo sviluppo di nuove tecnologie alimentari possiamo optare per alternative più sostenibili....

Ricevi notizie da GEA

Resta in contatto con le innovazioni e le storie GEA iscrivendoti alle news di GEA.

Contattaci

Siamo qui per aiutarti! Solo pochi dettagli e saremo in grado di rispondere alla tua richiesta.